UFLEX

Feature:

Multiple feature

Composite material complement the feature of each other. Fluoropolymer liner for chemical and heat resistance, and rubber cover for vibration absorption.

Pressure Resistance

Besides the fluoropolymer liner, the tire cord withstanding internal pressure. Maximum design pressure is up to 1.6MPa, (16.3kgf/cm2), and a negative-pressure of minus 0.086MPa, (minus 650mmHg).

Download

For a comprehensive overview of the product specifications mentioned above, feel free to download the product catalog here.

Safety

The exterior rubber absorbs unexpected impacts and protection cover is not required for exposed applications.

Hot-water supply line

Fluoropolymer liner with a maximum operating temperature of up to 100°C. U-FLEX is suitable for hot-water supply application without any contamination.

Aplication:

Vibration absorption for equipment, such as pumps.

Dimensions

Nominal Dia. [Dimension mm.] Mass [KG] Allowable Movement [mm] Installation Tolerances [mm]
mm inch L Ød T Eccentricity Elongation Compression Deflection angle Eccentricity Elongation Compression Deflection angle
20 3/4 74 25 23 2.0 10 10 10 10 ̊ 4 3 3 5 ̊
25 1 74 25 23 3.5 10 10 10 10 ̊ 4 3 3 5 ̊
32 1 1⁄4 74 40 25 3.9 10 10 10 10 ̊ 4 3 3 5 ̊
40 1 1⁄2 74 40 25 4.3 10 10 10 10 ̊ 4 3 3 5 ̊
50 2 104 53 25 5.1 10 10 10 10 ̊ 4 3 3 5 ̊
60 2 1⁄2 106 65 27 6.9 10 10 10 10 ̊ 4 3 3 5 ̊
80 3 106 75 27 6.9 10 10 10 10 ̊ 4 3 3 5 ̊
100 4 115 101 27 8.5 10 10 10 10 ̊ 4 3 3 5 ̊
125 5 135 122 32 14 10 10 10 10 ̊ 4 3 3 5 ̊
150 6 135 145 34 17 10 10 10 10 ̊ 4 3 3 5 ̊
200 8 135 195 34 20 10 10 10 10 ̊ 4 3 3 5 ̊
250 10 140 250 38 32 10 10 10 10 ̊ 4 3 3 5 ̊
300 12 140 305 38 33 10 10 10 10 ̊ 4 3 3 5 ̊
  • Mass is the data when the material is SS400, and the flange is JIS10K.
  • Use a joint within the range of allowable displacement.
  • Fixing allowable displacement = fixing time displacement + allowable
    operational displacement.
  • Each displacement in the chart is considered as single displacement,
    so for multiple displacements, correction is necessary. Referring to
    “Attention for handling or TOZEN HP”.
  • Referring to “fixing bolt dimension table”, and use fixing bolt. Nut
    is not necessary. (When companion flange is JIS 10K, material is
    SS400, and when plain washer and gasket are not used.)
No Parts Material
1 Liner Fluorine resin
2 Inner Rubber EPDM(SK10)
3 Reinforcing cord Aramid fiber
4 Reinforcing ring SWRH
5 Outer Rubber EPDM(SK10)
6 Spring flange SS400
7 Reinforcing flange SS400
Flange Compatible Dimension Standard JIS10K  
Flange standard can be changed to X JIS5K  
O PN16  
O JIS20K  
O ANSI 20A-32A can't be manufactured
Material Standart SS400  
Flange standard can be changed to X FCD  
O SS304  
O SUS316  
X Polyvinyl chloride  

Installation

Pump installation, such as hot-water supply lines, chemical lines, and pure water lines.

Operation Conditions and Performance